@ -2723,7 +2723,7 @@ Data displayed in this mode is in essence very similar to the instrumentation on
|
||||
|
||||
First and foremost, the presented information is constructed from a number of call stack samples, which represent real addresses in the application's binary code, mapped to the line numbers in the source files. This reverse mapping may not be always possible, or may be erroneous. Furthermore, due to the nature of the sampling process, it is impossible to obtain exact time measurement. Instead, time values are guesstimated by multiplying number of sample counts by mean time between two distinct samples.
|
||||
|
||||
The \emph{Name} column contains name of the function in which the sampling was done. If the \emph{\faSitemap{}~Inlines} option is enabled, functions which were inlined will be preceded with a '\faCaretRight{}' symbol and additionally display their parent function name in parenthesis. Otherwise, only non-inlined functions are listed, with count of inlined functions in parenthesis. Any entry containing inlined function may be expanded to display the corresponding functions list (some functions may be hidden if the \emph{\faPuzzlePiece{}~Show all} option is disabled, due to lack of sampling data). Clicking on a function name will open the call stack sample parents window (see chapter~\ref{sampleparents}). Note that if inclusive times are displayed, listed functions will be partially or completely coming from mid-stack frames, which will prevent, or limit the capability to display parent call stacks.
|
||||
The \emph{Name} column contains name of the function in which the sampling was done. If the \emph{\faSitemap{}~Inlines} option is enabled, functions which were inlined will be preceded with a '\faCaretRight{}' symbol and additionally display their parent function name in parenthesis. Otherwise, only non-inlined functions are listed, with count of inlined functions in parenthesis. Any entry containing inlined function may be expanded to display the corresponding functions list (some functions may be hidden if the \emph{\faPuzzlePiece{}~Show all} option is disabled, due to lack of sampling data). Clicking on a function name will open the sample entry call stacks window (see chapter~\ref{sampleparents}). Note that if inclusive times are displayed, listed functions will be partially or completely coming from mid-stack frames, which will prevent, or limit the capability to display parent call stacks.
|
||||
|
||||
The \emph{Location} column displays the corresponding source file name and line number. Depending on the \emph{Location} option selection it can either show function entry address, or the instruction at which the sampling was performed. The \emph{Entry} mode points at the beginning of a non-inlined function, or at the place where inlined function was inserted in its parent function. The \emph{Sample} mode is not useful for non-inlined functions, as it points to one randomly selected sampling point out of many that were captured. However, in case of inlined functions, this random sampling point is within the inlined function body. Using these options in tandem enable you to look at both the inlined function code and the place where it was inserted. If the \emph{Smart} location is selected, profiler will display entry point position for non-inlined functions and sample location for inlined functions. Selecting the \emph{\faAt{}~Address} option will instead print the symbol address.
|
||||
|
||||
@ -3089,7 +3089,7 @@ Stack frame location may be displayed in the following number of ways, depending
|
||||
|
||||
In some cases it may be not possible to properly decode stack frame address. Such frames will be presented with a dimmed '\texttt{[ntdll.dll]}' name of the image containing the frame address, or simply '\texttt{[unknown]}' if even this information cannot be retrieved. Additionally, '\texttt{[kernel]}' is used to indicate unknown stack frames within the operating system internal routines.
|
||||
|
||||
If the displayed call stack is a sampled call stack (chapter~\ref{sampling}), an additional button will be available, \emph{\faDoorOpen{}~Global entry statistics}. Clicking it will open the call stack sample parents window (chapter~\ref{sampleparents}) for the current call stack.
|
||||
If the displayed call stack is a sampled call stack (chapter~\ref{sampling}), an additional button will be available, \emph{\faDoorOpen{}~Global entry statistics}. Clicking it will open the sample entry call stacks window (chapter~\ref{sampleparents}) for the current call stack.
|
||||
|
||||
Clicking on the \emph{\faClipboard{}~Copy to clipboard} button will copy call stack to the clipboard.
|
||||
|
||||
@ -3121,10 +3121,10 @@ At the first glance it may look like \texttt{unique\_ptr::reset} was the \emph{c
|
||||
|
||||
Moreover, the linker may determine in some rare cases that any two functions in your program are identical\footnote{For example if all they do is zero-initialize a region of memory. As some constructors would do.}. As a result, only one copy of the binary code will be provided in the executable for both functions to share. While this optimization produces more compact programs, it also means that there's no way to distinguish the two functions apart in the resulting machine code. In effect, some call stacks may look nonsensical until you perform a small investigation.
|
||||
|
||||
\subsection{Call stack sample parents window}
|
||||
\subsection{Sample entry call stacks window}
|
||||
\label{sampleparents}
|
||||
|
||||
This window displays statistical information about the selected symbol. All sampled call stacks (chapter~\ref{sampling}) leading to the symbol are counted and displayed in descending order. You can select the displayed call stack using the \emph{parent call stack} controls, which also display time spent in the chosen call stack. Alternatively, sample counts may be shown by disabling the \emph{\faStopwatch{}~Show time} option, which is described in more detail in chapter~\ref{statisticssampling}.
|
||||
This window displays statistical information about the selected symbol. All sampled call stacks (chapter~\ref{sampling}) leading to the symbol are counted and displayed in descending order. You can select the displayed call stack using the \emph{entry call stack} controls, which also display time spent in the chosen call stack. Alternatively, sample counts may be shown by disabling the \emph{\faStopwatch{}~Show time} option, which is described in more detail in chapter~\ref{statisticssampling}.
|
||||
|
||||
The layout of frame list and the \emph{\faAt{}~Frame location} option selection is similar to the call stack window, described in chapter~\ref{callstackwindow}.
|
||||
|
||||
@ -3246,7 +3246,7 @@ If automated call stack sampling (see chapter~\ref{sampling}) was performed, add
|
||||
|
||||
Instruction timings can be viewed as a group. To begin constructing such group, click the \LMB{}~left mouse button on the percentage value. Additional instructions can be added using the \keys{\ctrl}~key, while holding the \keys{\shift}~key will allow selection of a range. To cancel the selection, click the \RMB{}~right mouse button on a percentage value. Group statistics can be seen at the bottom of the pane.
|
||||
|
||||
Clicking the \MMB{}~middle mouse button on the percentage value of an assembly instruction will display call stack parents of the selected sample (see chapter~\ref{sampleparents}). This functionality is only available for instructions that have collected sampling data, and only in the assembly view, as the source code may be inlined multiple times, which would result in ambiguous location data.
|
||||
Clicking the \MMB{}~middle mouse button on the percentage value of an assembly instruction will display entry call stacks of the selected sample (see chapter~\ref{sampleparents}). This functionality is only available for instructions that have collected sampling data, and only in the assembly view, as the source code may be inlined multiple times, which would result in ambiguous location data. Note that number of entry call stacks is displayed in a tooltip, for a quick reference.
|
||||
|
||||
Sample data source is controlled by the \emph{\faSitemap{}~Function} control, in the window header. If this option should be disabled, sample data will represent the whole symbol. If it is enabled, then the sample data will only include the selected function. The currently selected function can be changed by opening the drop-down box, which includes time statistics. The time percentage values of each contributing function are calculated relative to total number of samples collected within the symbol.
|
||||
|
||||
|