5 Commits

Author SHA1 Message Date
James Molloy
3e1ce05752 [AArch64] Fixup test after r281160
How I missed this locally is beyond me. I suspect llc didn't recompile. This is just changing the CHECK line back to what it was before r280364.

llvm-svn: 281161
2016-09-11 08:24:04 +00:00
James Molloy
88cad7e5cf [SimplifyCFG] Handle tail-sinking of more than 2 incoming branches
This was a real restriction in the original version of SinkIfThenCodeToEnd. Now it's been rewritten, the restriction can be lifted.

As part of this, we handle a very common and useful case where one of the incoming branches is actually conditional. Consider:

   if (a)
     x(1);
   else if (b)
     x(2);

This produces the following CFG:

         [if]
        /    \
      [x(1)] [if]
        |     | \
        |     |  \
        |  [x(2)] |
         \    |  /
          [ end ]

[end] has two unconditional predecessor arcs and one conditional. The conditional refers to the implicit empty 'else' arc. This same pattern can also be caused by an empty default block in a switch.

We can't sink the call to x() down to end because no call to x() happens on the third incoming arc (assume that x() has sideeffects for the sake of argument; if something is safe to speculate we could indeed sink nevertheless but this cannot happen in the general case and causes many extra selects).

We are now able to detect this case and split off the unconditional arcs to a common successor:

         [if]
        /    \
      [x(1)] [if]
        |     | \
        |     |  \
        |  [x(2)] |
         \   /    |
     [sink.split] |
           \     /
           [ end ]

Now we can sink the call to x() into %sink.split. This can cause significant code simplification in many testcases.

llvm-svn: 280364
2016-09-01 12:58:13 +00:00
James Molloy
76c9d423a7 Revert "[SimplifyCFG] Handle tail-sinking of more than 2 incoming branches"
This reverts commit r280217. r280216 caused buildbot failures - backing out the entire chain.

llvm-svn: 280233
2016-08-31 13:16:45 +00:00
James Molloy
c53b40b509 [SimplifyCFG] Handle tail-sinking of more than 2 incoming branches
This was a real restriction in the original version of SinkIfThenCodeToEnd. Now it's been rewritten, the restriction can be lifted.

As part of this, we handle a very common and useful case where one of the incoming branches is actually conditional. Consider:

   if (a)
     x(1);
   else if (b)
     x(2);

This produces the following CFG:

         [if]
        /    \
      [x(1)] [if]
        |     | \
        |     |  \
        |  [x(2)] |
         \    |  /
          [ end ]

[end] has two unconditional predecessor arcs and one conditional. The conditional refers to the implicit empty 'else' arc. This same pattern can also be caused by an empty default block in a switch.

We can't sink the call to x() down to end because no call to x() happens on the third incoming arc (assume that x() has sideeffects for the sake of argument; if something is safe to speculate we could indeed sink nevertheless but this cannot happen in the general case and causes many extra selects).

We are now able to detect this case and split off the unconditional arcs to a common successor:

         [if]
        /    \
      [x(1)] [if]
        |     | \
        |     |  \
        |  [x(2)] |
         \   /    |
     [sink.split] |
           \     /
           [ end ]

Now we can sink the call to x() into %sink.split. This can cause significant code simplification in many testcases.

llvm-svn: 280217
2016-08-31 10:46:33 +00:00
Yi Jiang
e0b3499db7 Avoid redundant select node in early if-conversion pass
llvm-svn: 240072
2015-06-18 22:34:09 +00:00