[mlir] Add support for custom readProperties/writeProperties methods.
Currently, operations that opt-in to adopt properties will see auto-generated readProperties/writeProperties methods to emit and parse bytecode. If a dialects opts in to use `usePropertiesForAttributes`, those definitions will be generated for the current definition of the op without the possibility to handle attribute versioning.
The patch adds the capability for an operation to define its own read/write methods for the encoding of properties so that versioned operations can handle upgrading properties encodings.
In addition to this, the patch adds an example showing versioning on NamedProperties through the dialect version API exposed by the reader.
Reviewed By: mehdi_amini
Differential Revision: https://reviews.llvm.org/D155340
This makes the bytecode reader/writer work on big-endian platforms.
The only problem was related to encoding of multi-byte integers,
where both reader and writer code make implicit assumptions about
endianness of the host platform.
This fixes the current test failures on s390x, and in addition allows
to remove the UNSUPPORTED markers from all other bytecode-related
test cases - they now also all pass on s390x.
Also adding a GFAIL_SKIP to the MultiModuleWithResource unit test,
as this still fails due to an unrelated endian bug regarding
decoding of external resources.
Differential Revision: https://reviews.llvm.org/D153567
Reviewed By: mehdi_amini, jpienaar, rriddle
Currently desired bytecode version is clamped to the maximum. This allows requesting bytecode versions that do not exist. We have added callsite validation for this in StableHLO to ensure we don't pass an invalid version number, probably better if this is managed upstream. If a user wants to use the current version, then omitting `setDesiredBytecodeVersion` is the best way to do that (as opposed to providing a large number).
Adding this check will also properly error on older version numbers as we increment the minimum supported version. Silently claming on minimum version would likely lead to unintentional forward incompatibilities.
Separately, due to bytecode version being `int64_t` and using methods to read/write uints, we can generate payloads with invalid version numbers:
```
mlir-opt file.mlir --emit-bytecode --emit-bytecode-version=-1 | mlir-opt
<stdin>:0:0: error: bytecode version 18446744073709551615 is newer than the current version 5
```
This is fixed with version bounds checking as well.
Reviewed By: mehdi_amini
Differential Revision: https://reviews.llvm.org/D151838
Add method to set a desired bytecode file format to generate. Change
write method to be able to return status including the minimum bytecode
version needed by reader. This enables generating an older version of
the bytecode (not dialect ops, attributes or types). But this does not
guarantee that an older version can always be generated, e.g., if a
dialect uses a new encoding only available at later bytecode version.
This clamps setting to at most current version.
Differential Revision: https://reviews.llvm.org/D146555